Automation & Vision Systems
| Accuracy class | 0,5 |
| Nominal characteristic value (sensitivity) | 1m V/V |
| Combined error | < 0,5 % |
| Characteristic value tolerance | 0,20% |
| Measuring principle | Full bridge strain gauge |
| Nom. resistance of strain gauge bridge | 700 Ohm |
| Bridge supply voltage | 10 V (nominal value) |
| 14 V (max. permissible value) | |
| Area | Max. 0 to 18 mV (at 1.8 x nominal force and 10 V bridge supply) |
| Mechanical stop | 1.2 to 1.8 x FN depending on type |
| Operating load | 1,2 to 1,8 FN |
| Limit load | 10 x FN |
| Nominal measuring deflection | 0.15 to 0.25 mm depending on type |
| Nominal temperature range | - 10 to + 60° C |
| Operating temperature range | - 10 to + 70° C |
| Temperature coefficient | ±0,3 %/10 K (characteristic value) |
| ±0,3 %/10 K (zero point)) | |
| Protection rating | IP 50 |
| Permissible axial lateral force | Max. 1 x FN |
| Connection cable | 6 x 0.14 mm2 , 5 m/10 m long |
| sensor roller PD 30 | |||||||||
| Type | ø d (mm) | NB min. (mm) | NB max. (mm) | L min. (mm) | ø d (mm) | Thread | Nominal measuring force FN per roller (kN) | ||
| PD 3008 | 80 | 300 | 1200 | NB + 10 | 20 | M 12 | 0,2 | 0,4 | 1 |
| PD 3010 | 100 | 300 | 1800 | NB + 10 | 20 | M 12 | 0,3 | 0,6 | 1,5 |
| PD 3012 | 120 | 400 | 2500 | NB + 10 | 20 | M 12 | 0,3 | 0,6 | 1,5 |
| PD 3016 | 160 | 600 | 3000 | NB + 10 | 40 | M 16 | 0,62 | 1,2 | 3 |
| PD 3020 | 200 | 600 | 3000 | NB + 10 | 40 | M 16 | 0,6 | 1,2 | 3 |
| roller surface PD 30 | |
| Surface index | Surface |
| 01 | Bare Ra 3.2 (standard) |
| 02 | Wound with rubber cork |
| 03 | Fine blasted with glass corundum Ra 6.3, hard anodized, layer thickness 30 μm 450 HV |
| 04 | Hard anodized, Ra 3.2, layer thickness 30 μ m 450 HV |
| 05 | Spiral groove left + right, pitch 40 mm, groove radius 6 mm, groove depth 0.25 mm |
| 13 | Rough blasted with glass corundum Ra 12.5, hard anodized, layer thickness 30 μm 450 HV |