Automation & Vision Systems
Changing web widths and web positions require a wide range of linear positioning systems. E+L positioning systems make it possible to use, in a single unit, up to four completely independent adjustment units positioned along the web. Depending on the requirements, these units can e.g. move sensors or cutters to the required position.
| Operating voltage | |
| Nominal value | 24 V DC |
| Nominal range | 20 to 30 V DC (ripple included) |
| Current consumption | 1.4 A DC (1 positioning drive) |
| 2.4 A DC (2 positioning drive) | |
| Nominal operating width | Min. 160 mm - Max. 5840 mm |
| Nominal actuating speed | 1 to 100 mm/s |
| Nominal actuating force (axial) | 20 N |
| Support load | Max. 50 N |
| Moment M1, M2, M3 | Max. 2 Nm |
| Positioning accuracy | ≤ ±0.1 mm (per slide) |
| Ambient temperature | +10 °C to +50 °C |
| Storage temperature | -25°C to +80 °C |
| Ambient conditions | Dry |
| Relative humidity | 15 to 95 % (non-condensing) |
| Certifications | Declaration of incorporation according to |
| Machinery Directive 2006/42/EC | |
| NRTL certificate CU 72210743 01 | |
| Protection rating | IP 54 |
| Interface ("Standard/UDP" variant) | Ethernet protocol EL.NET, Ethernet UDP |
| Interface optional ("Connect" variant) | Ethernet/IP, Profinet |
| Electrical connections VSB80 | |
| Operating voltage 24 V DC | Spring terminal |
| Operating voltage AG 9 | M12 connector, L-coded |
| Communication AG 9 | M8 connector, D-coded |
| Sensor CAN | 2 x M8 connectors |
| Sensor PoE | 2 x M8 connectors |
| Ethernet networking | 3 x M8 connectors |
| Digital inputs (configurable) | 10 x spring terminals |
| Digital outputs (configurable) | 2 x spring terminals |