Automation & Vision Systems
| Measuring interval | 1000/1500/2000/2500/3000 mm |
| Web speed | Max. 100m/min |
| Number of cameras | 2 to 6 |
| Camera position | Camera can be positioned over the conveyor belt |
| Fixed camera project-specific | |
| Field of view matrix camera | 60 x 60 mm |
| Displayed resolution | 0,1 mm |
| Measuring accuracy for length up to 100 m/min | ±0,4 mm |
| Measuring equipment capability (Cg&Cgk): [TW* = 10 x accuracy] | ≥1,67 |
| Interface | EtherNet/IP / Profibus / Profinet / CC Link / Device net |
| Relative humidity | 15 to 95 % (non-condensing) |
| Ambient temperature | +10 °C to +50 °C |
| Operating voltage | 115 to 230 V, 50/60 Hz |
| Current consumption | 16 A |
| Protection rating | IP 54 |