Accuracy class | 1 |
Nominal characteristic value (sensitivity) | 1m V/V |
Combined error | < 1 % |
Characteristic value tolerance | 0,20% |
Measuring principle | Full bridge strain gauge |
Nom. resistance of strain gauge bridge | 700 Ohm |
Bridge supply voltage | 10 V (nominal value) |
| 14 V (max. permissible value) |
Output voltage | |
Nominal range | 0 to 10 mV (for nominal force and 10 V bridge supply) |
Area | Max. 0 to 18 mV (at 1.8 x nominal force and 10 V bridge supply) |
Mechanical stop | 1.2 to 1.8 x FN depending on type |
Operating load | 1.2 to 1.8 x FN |
Limit load | 10 x FN |
Nominal measuring deflection | 0.15 to 0.25 mm depending on type |
Nominal temperature range | -10 °C to +60 °C |
Operating temperature range | -10 °C to +70 °C |
Temperature coefficient | ±0.3 %/10 K (characteristic value) |
| ±0.3 %/10 K (zero point) |
Protection rating | IP 50 |
Permissible axial lateral force | Max. 1 x FN |
Connection cable | 6 x 0.14 mm2, 5 m/10 m long |