| Accuracy class | 1 |
| Nominal characteristic value (sensitivity) | 1m V/V |
| Combined error | < 1 % |
| Characteristic value tolerance | 0,20% |
| Measuring principle | Full bridge strain gauge |
| Nom. resistance of strain gauge bridge | 700 Ohm |
| Bridge supply voltage | 10 V (nominal value) |
| | 14 V (max. permissible value) |
| Output voltage | |
| Nominal range | 0 to 10 mV (for nominal force and 10 V bridge supply) |
| Area | Max. 0 to 18 mV (at 1.8 x nominal force and 10 V bridge supply) |
| Mechanical stop | 1.2 to 1.8 x FN depending on type |
| Operating load | 1.2 to 1.8 x FN |
| Limit load | 10 x FN |
| Nominal measuring deflection | 0.15 to 0.25 mm depending on type |
| Nominal temperature range | -10 °C to +60 °C |
| Operating temperature range | -10 °C to +70 °C |
| Temperature coefficient | ±0.3 %/10 K (characteristic value) |
| | ±0.3 %/10 K (zero point) |
| Protection rating | IP 50 |
| Permissible axial lateral force | Max. 1 x FN |
| Connection cable | 6 x 0.14 mm2, 5 m/10 m long |