Accuracy class | 0,1 |
Operating voltage | 24 V DC (18 to 30 V DC) |
Current consumption | 0,2 A |
Strain gauge amplifier | 2 channels |
Input voltage | ±25 mV, 14 bits |
Bridge supply voltage | 10 VDC |
Measuring cycle time | 1 ms |
Analog outputs: | |
Actual signal, direct | 1 x 0 to 5/10 V |
| 1 x 0/4 to 20 mA, Rmax 500 Ω |
Actual signal, filtered | 1 x 0 to 5/10 V, fg=0.2 to 20 Hz |
Output signal (configurable) | Total signal/channel 1/channel 2/difference signal |
Digital outputs | 3 x floating, short circuit-proof |
Output voltage | 24 V, max. 500 mA |
Output signal (configurable) | Limit/Alarm/Status |
Digital input | 1 x floating |
Input voltage | 24 V DC |
Input signal (configurable) | Tare / recipe / stop recording |
Display and control unit | Color touchscreen (LCD) |
Interfaces | 1 x RJ45, 100 Mbits |
| EtherNet/IP (ODVA-compliant) or UDP/IP |
Nominal operating temperature | +10 °C to +50 °C |
Relative humidity | 15 to 95 % (non-condensing) |
Protection rating | IP 20 (plug-in) |
| IP 54 (with housing) |
Dimensions (W x H x D) | 100 x 100 x 50 mm (plug-in) |
| 130 x 155 x 106 mm (with housing) |
| 90 x 90 x 90 mm (top-hat rail mounting) |