Automation & Vision Systems
Accuracy class | 0.1 |
Operating voltage | |
Nominal value | 24 V DC |
Nominal range (ripple included) | 18 to 30 V DC |
Nominal operating temperature | 10 °C to +50 °C |
Relative humidity | Max. 95%, non-condensing |
Input voltage (strain gauge bridge) | 2 x 0 to ±25 mV, 14 Bit, t cycle =1 ms |
Analog outputs | 2 x voltage, 0 to +5/10 V DC, Imax 10 mA |
1 x current, 0/4 to 20 mA, Rmax 500 Ω | |
Filtering | fg = 0.2 to 20 Hz |
Total signal/Channel 1/Channel 2/ | |
Differential signal (configurable) | |
Digital outputs | 3 x floating, short circuit proof, 24 V DC, Imax 0.5 A |
Limit/alarm/status (configurable) | |
Digital input | 1 x floating, 24 V DC |
Tare/recipe/stop recording (configurable) | |
Display and control unit | Color touch display (LCD) |
(not for PA 6202) | |
Interfaces | RJ45 Ethernet 100 Mbit for |
- Integrated web server | |
- Fieldbus Ethernet/IP | |
Protection class | PA 6200: IP 54 (when built-in) |
PA 6201: IP 54 | |
PA 6202: IP 20 |