| Accuracy class | 0,1 |
| Measuring cycle time | 1 ms |
| Strain gauge amplifier | 2 Kanäle |
| Input voltage | ±25 mV, 14 bits |
| Bridge supply voltage | 10 V DC |
| Analog outputs | |
| 2 x 0 bis 5/10 V | |
| 1 x 0/4 bis 20 mA, Rmax 500 Ω | |
| Filter | fg=0,2 bis 20 Hz |
| Output signal (configurable) | Total signal / channel 1 / channel 2 / difference signal |
| Digital outputs | 3 x floating, short-circuit proof |
| Output voltage | 24 V DC, Imax. 0,5 A |
| Output signal (configurable) | Limit/Alarm/Status |
| Digital input | 1 x floating |
| Input voltage | 24 V DC |
| Input signal (configurable) | Tare / Recipe / Stop recording |
| Display and control unit | Color touch display (LCD) (not PA 62.2) |
| Interface | RJ45 Ethernet 100 Mbit (ODVA-compliant) |
| Fieldbus EtherNet/IP, Profinet or UDP | |
| Operating voltage | 24 V DC |
| Nominal range | 18 V bis 30 V DC (incl. ripple) |
| Current consumption | 0.2 A |
| Ambient temperature | +10 °C to +50 °C |
| Protection rating | IP 20 (top-hat rail mounting) |
| IP 54 (panel mounted kit and housing) | |
| Dimensions (L x W x H)/weight | |
| Panel mounted kit | 100 x 100 x 50 mm/ 0,44 kg |
| Housing | 155x 130x 106 mm / 1,8 kg |
| Top-hat rail mounting | 90 x 90 x 90 mm / 0,35 kg |