Automation & Vision Systems
Accuracy class | 0.5 |
Nominal characteristic value (sensitivity) | 1 m V/V |
Combined error (hysteresis/non-linearity) | < 0.5% |
Characteristic value tolerance | 0.2% |
Measuring principle | Full bridge strain gauge |
Nominal resistance of the strain gauge bridge | 700 Ohm |
Bridge supply voltage | |
Nominal value | 10 V |
Max. permissible value | 14 V |
Mechanical stop | 1.8 to 2.4 FN dep. on type |
Operating load | 1.8 to 2.4 FN |
Limit load | 20xFN |
Nominal measuring deflection | 0.1 to 0.2 mm depending on type |
Nominal temperature range | -10 °C to +60 °C |
Operating temperature range | -10 °C to +90 °C |
Temperature coefficient | |
of characteristic value | ±0.3% / 10 K |
of the zero signal | ±0.3% / 10 K |
Protection class | IP 65 |
Max. permissible axial transverse force | 1xFN |