Automation & Vision Systems
| Accuracy class | 0.5 |
| Nominal characteristic value (sensitivity) | 1 m V/V |
| Combined error (hysteresis/non-linearity) | < 0.5% |
| Characteristic value tolerance | 0.2% |
| Measuring principle | Full bridge strain gauge |
| Nominal resistance of the strain gauge bridge | 700 Ohm |
| Bridge supply voltage | |
| Nominal value | 10 V |
| Max. permissible value | 14 V |
| Mechanical stop | 1.8 to 2.4 FN dep. on type |
| Operating load | 1.8 to 2.4 FN |
| Limit load | 20xFN |
| Nominal measuring deflection | 0.1 to 0.2 mm depending on type |
| Nominal temperature range | -10 °C to +60 °C |
| Operating temperature range | -10 °C to +90 °C |
| Temperature coefficient | |
| of characteristic value | ±0.3% / 10 K |
| of the zero signal | ±0.3% / 10 K |
| Protection class | IP 65 |
| Max. permissible axial transverse force | 1xFN |