Automation & Vision Systems
Accuracy class | 0.5 |
Nominal characteristic value (sensitivity) | 1 m V/V |
Combined error | < 0.5% |
Characteristic value tolerance | 0.2% |
Measuring principle | Full bridge strain gauge |
Nominal resistance of the strain gauge bridge | 700 Ohm |
Bridge supply voltage | 10 V (nominal value) |
14 V (max. permissible value) | |
Mechanical stop | 1.8 to 2.4 FN dep. on type |
Operating load | 1.8 to 2.4 FN |
Limit load | 20xFN |
Nominal measuring deflection | 0.1 to 0.2 mm depending on type |
Nominal temperature range | -10 °C to +60 °C |
Operating temperature range | -10 °C to +90 °C |
Temperature coefficient | ± 0.3 % / 10 K (characteristic value) ± 0.3 % / 10 K (zero signal) |
Protection class | IP 50 |
Max. permissible axial transverse force | 1xFN |
Weight | 2.3 kg (d = 17 mm), 3.6 kg (d = 25 mm), 8.5 kg (d = 35 mm) |
Type, bore on one side | Type, bore on both sides | d** (mm) | Nominal measuring force (kN) | ||||
PD 2112 | PD 2212 | 12 | 0,05 | 0,1 | 0,2 | 0,5 | 1 |
PD 2115 | PD 2215 | 15 | 0,05 | 0,1 | 0,2 | 0,5 | 1 |
PD 2117 | PD 2217 | 17 | 0,05 | 0,1* | 0,2 | 0,5* | 1 |
PD 2120 | PD 2220 | 20 | 0,15 | 0,3 | 0,75 | 1,5 | |
PD 2125 | PD 2225 | 25 | 0,15* | 0,3 | 0,75* | 1,5 | |
PD 2130 | PD 2230 | 30 | 0,3 | 0,6 | 1,5 | 3 | |
PD 2135 | PD 2235 | 35 | 0,3* | 0,6 | 1,5* | 3 | |
PD 2140 | PD 2240 | 40 | 0,6 | 1,2 | 3 | 6 | |
PD 2145 | PD 2245 | 45 | 0,6 | 1,2 | 3 | 6 | |
PD 2150 | PD 2250 | 50 | 0,6* | 1,2 | 3* | 6 | |
PD 2155 | PD 2255 | 55 | 1 | 2 | 5 | 10 | |
PD 2160 | PD 2260 | 60 | 1 | 2 | 5 | 10 | |
PD 2165 | PD 2265 | 65 | 1 | 2 | 5 | 10 | |
*Preferred sizes | **Diameter of the axle journal |