Automation & Vision Systems
Accuracy class | 0.5 |
Nominal characteristic value (sensitivity) | 1 m V/V |
Combined error | < 0.5% |
Characteristic value tolerance | 0.20% |
Measuring principle | Full bridge strain gauge |
Nominal resistance of the strain gauge bridge | 700 Ohm |
Bridge supply voltage, nominal value | 10 V |
Bridge supply voltage, max. permissible value | 14 V |
Mechanical stop | 1.8 to 2.4 FN dep. on type |
Operating load | 1.8 to 2.4 FN |
Limit load | 20xFN |
Nominal measuring deflection | 0.1 to 0.2 mm depending on type |
Nominal temperature range | -10 °C to +60 °C |
Operating temperature range | -10 °C to +90 °C |
Temperature coefficient | "± 0.3 % / 10 K (characteristic value) |
± 0.3 % / 10 K (zero signal)" | |
Protection class | IP 50 |
Max. permissible axial transverse force | 1xFN |
Weight | "2.3 kg (d1 = 17 mm), |
3.6 kg (d1 = 25 mm), | |
8.5 kg (d1 = 35 mm)" |