Automation & Vision Systems
Accuracy class | 1 |
Hysteresis | ±0.15 % |
Non-linearity | ±0.15 % |
Reproducibility | ±0.1 % |
Temperature coefficient | ±0.05 % / 10 K |
Measuring principle | Full bridge strain gauge |
Nominal resistance of the strain gauge bridge | 4 x 350 Ohm |
Nominal characteristic value | 2 mV / V |
Output voltage | 0 to 20 mV (at FN and UB 10 V) |
Mechanical stop | 1.1xFN (0 to 22 mV and UB 10 V) |
Nominal measuring deflection | 0.2 to 2 mm depending on type |
Axial transverse force | Not allowed |
"Operating voltage | |
Nominal value" | 10 V DC |
Ambient temperature | +20 to +160 °C |
Protection class | IP 67 |