Automation & Vision Systems
Measuring range (basis weight measurement) | Up to 4000 g/m² |
Measuring accuracy | <± 0.5% of the basis weight of the calibration piece |
Resolution | 0.001 g/m² |
Sensor type | US Ultrasonic sensor |
Measuring point size | Ø 25 mm |
Cycle time of the measuring system | 120 Hz |
Passage height | 40 mm (from measuring head to measuring head) |
Height fluctuation of the web | ±5 mm in the middle; no fluttering |
Max. actuating speed (only for variants with crossbeam) | 150 mm/s |
Relative humidity | max. 95 % (non-condensing) |
Ambient temperature | +10 °C to +50 °C |
Ambient temperature at the sensor | +10 °C to +70 °C |
Storage temperature | -20 °C to +80 °C |
Certification (optional) | UL/CSA |
Operating voltage | 24 V DC, 4 A (10 A for variant with crossbeam) |
Nominal width (NW) | 130 mm (5‘‘) to 610 mm (24‘‘) (larger widths on request) |
Dimensions | L (NW+ 228 mm) x H 144 mm x D 140 mm |
Measurement of the basis weight (current, average, min. & max., basis weight profile over the entire width) | |
Comparison of nominal and measured values | |
Tolerances | Tolerances for warning and alarm if target exceeded or dropped below |
Data output | To PLC, to ELQ, to I/O |
User levels/password | Operator level: Limited access rights Engineer level: Full access rights |
WBM Interface | Web-based administration Configuration and value display accessible via web browser |