FW: 40 | +/-0.3 mm (+/-0.4 mm at 480 mm) |
FW: 100 | +/-0.4 mm (+/-0.5 mm at 480 mm) |
Reproducibility | ±0.1 mm |
Wavelength | 850 nm |
Scanning rate | 500 Hz (≤ 2ms) |
Evaluation, edge number | Max. 4 edges (2 webs) |
Operating voltage nominal value | nominal range | 24 V DC | 20 to 30 V DC (ripple included) |
Interface FR 62 | Sensor CAN |
Interface FR 61 | Ethernet PoE (Power over Ethernet) |
Fieldbuses | Ethernet UDP, Ethernet IP (in preparation) |
Electrical connection | M 8 socket connector 6-pin (Sensor CAN) |
| M 8 socket connector 4-pin (Ethernet PoE) |
Air purge system operating pressure | 2 bar |
Air purge system air consumption | 1.55 m³/h (at 2 bar) |
Service unit filter | 5 µm |
Service unit residual oil content | < 0.01 mg / m³ |
Pneumatic connection | Plastic hose, outer diameter |
| 6 mm externally calibrated |
Ambient temperature | +10 °C to +50 °C |
Temperature drift | ≤ ±0.1 mm/10 K |
Storage temperature | -10 °C to +80 °C |
Relative humidity | 15 to 95 % (non-condensing) |
Protection class | IP 54 |
Certification | CE conformity |
| ± 80 mm FW 40 mm | 226 x 115 x 32 mm |
Measuring range | Dimensions (L x W x H) | ± 160 mm FW 40 mm | 386 x 115 x 32 mm |
| ± 240 mm FW 40 mm | 546 x 115 x 32 mm |
| ± 80 mm FW 104 mm | 226 x 175 x 32 mm |
| ± 160 mm FW 100 mm | 386 x 175 x 32 mm |
| ± 240 mm FW 100 mm | 546 x 175 x 32 mm |