Automation & Vision Systems
Measuring range (basis weight measurement) | Up to 800 g/m² |
Measuring accuracy | < ± 0.5% of the basis weight of the calibration piece |
Resolution | 0.001 g/m² |
Sensor type | US ultrasonic sensor |
Measuring point size | Ø 25 mm |
Cycle time of the measuring system | 120 Hz |
Passage height | 40 mm (from measuring head to measuring head) |
Height fluctuation of the web | ± 5 mm in the middle; no fluttering |
Actuating speed of sensor | 300 mm/s |
Relative humidity | 15 to 95 % (non-condensing) |
Ambient temperature | +10 to +50 °C |
Ambient temperature at the sensor | +10 to +70 °C |
Storage temperature | -20 to +80 °C |
Protection rating | IP 54, UL 50e: Type 12 |
Power supply | 24 V (optionally 100 to 250 V AC, 3.5 A, 50/60 Hz) |
Current consumption | Max. 10 A |
Nominal width | 500 to 2500 mm (larger widths on request) |
Dimensions | L (NB + 932 mm) x H 960 mm x D 270 mm |
Measurement of the basis weight (current, average, min. & max., basis weight profile over the entire width) | |
Comparison of nominal and measured values | |
Tolerances | Tolerances for values Warning / rejection limits |
Data output | To PLC, to ELQ, to I/O |
User levels/password | Operator level: Limited access rights Engineer level: Full access rights |
WBM Interface | Web-based administration Configuration and value display accessible via web browser |