Automation & Vision Systems
| Measuring range | ±3 mm |
| Deviation in linearity (Measuring range 10 to 90%) | ±1 % |
| Operational voltage | |
| Nominal value | 24 V DC |
| Nominal range (including ripple) | 20 bis 30 V DC |
| Power consumption | max. 80 mA DC |
| Transmission pulse frequency | 1 kHz |
| Ambient temperature | +10 °C to +50 °C |
| Storage temperature | -25 °C to +80 °C |
| Temperature drift (typical) with a relative humidity of 60% | ca. 0,025 mm/K |
| Scan rate | 200 Hz |
| Cable length | max. 10 m |
| Protection class | max. IP 54 with suitable connector inserted |
| Max. installation height | 0 to 3000 m above M.S.L. |
| Weight | 0,2 kg |
| Dimensions (L x W x H) | 76,2 x 27 x 92,4 mm |