Positional accuracy | < ± 0.2 mm (material-dependent) |
Error frequency | Max. 2 Hz |
Nominal actuating travel | See table |
Nominal actuating speed | 60 mm/s (AG 91), 30 mm/s (AG 93) |
Nominal actuating force | 1000 N (AG 91), 3000 N (AG 93) |
Ambient temperature | +10 °C to +50 °C (AG91/93 +10 °C to +60 °C) |
Storage temperature | -20 °C to +80 °C |
Relative humidity | 15 to 95 % (non-condensing) |
Operating voltage | |
Nominal value | 24 V DC |
Nominal range | 20 to 30 V DC (ripple included) |
Nominal range with power supply | 100 to 240 V, 50/60 Hz |
Current consumption | Max. 6.2 A DC (AG 91 with manual sensor positioning) |
| Max. 8.3 A DC (AG 93 with manual sensor positioning) |
| Max. 7.4 A DC (AG 91 with motorized sensor positioning) |
| Max. 9.5 A DC (AG 93 with motorized sensor positioning) |
Fieldbus interface, optional | Ethernet UDP, Ethernet IP, Profinet |
Certifications | Declaration of incorporation according to Machinery Directive 2006/42/EC |
| NRTL certificate CU72170613 04 (AG 91/93) |
| NRTL certificate CU 72210743 02 (DN 40) |
Protection class | IP 54 |