Automation & Vision Systems
Receiver/transmitter distance | 160 mm |
Operating voltage, nominal value | 24 V DC |
Operating voltage, nominal range | 20-30 V DC |
(ripple included) | |
Current draw | Max. 0.2 A |
Ambient temperature | +0 °C to + 60 °C |
Storage temperature | +0 °C to + 85 °C |
Measuring range | Dependent on the model |
Width measurement accuracy "Premium" | ±1 mm (depends on the condition of the web edge) |
Web position | Between transmitter and receiver |
Max. height fluctuation | ±10 mm |
Max. sensor cable length | 25 m |
Protection class | Max. IP 54 with suitable connector inserted |
Weight | Approx. 15 kg (AB 1600 mm) |
Approx. 30 kg (AB 3200 mm) | |
Scanning rate | 200 Hz |