Automation & Vision Systems
| Operating voltage, nominal value | 24 V DC |
| Operating voltage, nominal range (ripple included) | 20-30 V DC |
| Current consumption | 80 mA |
| Ambient temperature | +10 °C to +50 °C |
| Measuring range | ±10 mm |
| Resolution | 0.02 mm |
| Linearity | ±0.1 mm |
| Wavelength | 850 nm |
| Scanning rate | 200 Hz |
| Cable length | Max. 10 m |
| Protection class | IP 54 |
| Weight | 0.3 kg |
| Air purge system operating pressure | Min. 0.1 bar, max. 0.2 bar |
| Service unit filter | 5 µm |
| Service unit residual oil content | < 0.01 mg/m³ |
| Dimensions (LxWxH) | 105x50x40 mm |
| Fork width | See selection table, ELGUIDER brochure |