| Positional accuracy | ±5 mm (wide band sensor FE 45, standard resolution) |
| Correction range | ± 300 mm (depending on web width, infeed path and web type) |
| Spreading | 0 to 12 mm (factory setting 9 mm) |
| Web speed | max. 100 m/min |
| Web tension | max. 1000 N |
| Operating width | 1600 to 3600 mm (roller diameter 215 mm) |
| Operating voltage | 24 V DC |
| Ambient temperature | +0 to +100 °C |
| Ambient conditions | Damp, wet and saturated steam |
| Protection class inside the machine | IP 65 |