Automation & Vision Systems
| Accuracy class | 0.5 |
| Nominal characteristic value (sensitivity) | 2 mV/V |
| Combined error | ±0.5% |
| Characteristic value tolerance | < ±0.2% |
| Measuring principle | Full bridge strain gauge |
| Nominal resistance of the strain gauge bridge | 700 Ohm |
| Bridge supply voltage, nominal value | 10 V |
| Bridge supply voltage, max. permissible value | 14 V |
| Mechanical stop | 1.2xFN |
| Operating load | 1.2xFN |
| Limit load | 10xFN |
| Nominal measuring deflection | 0.2 to 0.3 mm depending on type |
| Nominal temperature range | -10 °C to +60 °C |
| Operating temperature range | -10 °C to +90 °C |
| Temperature coefficient | ±0.3% / 10 K (characteristic value) |
| ±0.3% / 10 K (zero signal) | |
| Protection class | IP 54 |
| Max. permissible axial lateral force | 1xFN |
| Weight | 1.5 kg |