Automation & Vision Systems
| Nominal measuring force FN | 60 N |
| Mechanical stop | 1.5 x FN |
| Operating load | 1.0 to 1.4 x FN |
| Limit load | 10 x FN |
| Max. permissible axial lateral force | 0.5 x FN |
| Nominal measuring deflection | 0.3 to 0.4 mm |
| Accuracy class | 0.5 |
| Resolution | 1:25 |
| Nominal characteristic value (sensitivity) | 1 mV/V |
| Characteristic value tolerance | 0.20% |
| Combined error | < 0.5 % |
| Measuring principle | DMS full bridge |
| Nominal resistance of the DMS bridge | 700 Ohm |
| Bridge supply voltage | |
| Nominal value | 10 V |
| Max. permissible value | 14 V |
| Output voltage | |
| Nominal value range | 0 to 10 mV (for nominal force and bridge supply voltage 10 V) |
| Maximum range | 0 to 15 mV (for 1.5 x nominal force and bridge supply voltage 10 V) |
| Nominal/ambient temperature | -10 to +60 °C |
| Usage temperature | -10 to +90 °C |
| Storage temperature | -10 to +90 °C |
| Temperature coefficient | |
| of the characteristic value | ±0.3 % / 10 K |
| of the zero signal | ±0.3 % / 10 K |
| Protection class | IP 54 |
| Weight | 3.3 kg |