Web tension load cell PD 2718

Product description
  • Reliable web tension monitoring helps avoid web tears and thus reduce producion costs.
  • E+L load cells continuously record the tension in the moving web and supply this value as an analog signal. As such, they provide the prerequisite for reliable web tension measuring and control.
Technical Specifications
Nominal measuring force FN60 N
Mechanical stop1.5 x FN
Normal load1.0 bis 1.4 x FN
Limit load10 x FN
Max. permissible axial lateral force0,5 x FN
Max. permissible wrapping180°
Nominal measuring path0,3 bis 0,4 mm
Precision class0,5
Resolution 1:25
Nominal characteristic value (sensitivity)1 mV/V
Characteristic value tolerance0,20%
Combined error < 0,5 %
Measuring principleFull strain gauge bridge
Nominal strain gauge bridge resistance700 Ohm
Bridge supply voltage
nominal value10 V
max. permissible value14 V
Output voltage
Nominal range0 bis 10 mV (with nominal force and a bridge supply voltage of 10 V)
Maximum range0 bis 15 mV (with 1.5 x nominal force and a bridge supply voltage of 10 V)
Nominal/ambient temperature-10 bis +60 °C
Service temperature-10 bis +90 °C
Storage temperature-10 bis +90 °C
Temperature coefficient
of the characteristic value±0,3 % / 10 K
of the zero signal±0,3 % / 10 K
Ambient conditionsfor use in dry and dusty conditions
Protection classIP 54
Weight3,3 kg
Product downloads

Order now!

  • Data Sheet