VWS Turning bar system

VWS Turning bar system
Product description
  • Individual adjustment of the turning bars to the machine environment
  • Control components and complete systems with turning bar available
  • Optional turning bar with pneumatic ventilation
Technical Specifications
Operating voltage, nominal value 24 V DC
Operating voltage, nominal range 20 to 30 V DC
Operating voltage nominal range with power supply 115 to 460 V, 50/60 Hz
Current consumption actuating drive AG 2491 1.6 A DC
Current consumption actuating drive AG 2591 3.6 A DC
Current consumption actuating drive AG 2691 5.6 A DC
Nominal width NW 400 to 3000 mm
Turning bar diameter 80/100/120/160/200 mm
Nominal actuating travel Max. ±25/50/75/100 mm
Actuating speed 25 mm/s
Web tension Max. 2000 N
Positional accuracy < ±1 mm (material-dependent)
Error frequency Max. 0.5 Hz
Ambient temperature +10 °C to +50 °C
Protection class IP 54
Measuring range, infrared edge sensor FR 52 ±10 mm
Measuring range, ultrasonic edge sensor FX 52 (FX 42) ±10 mm
Kontaktieren
Sie uns!

+49 (0)821/2435-0

Sie haben weitere Fragen? Wir beraten Sie gerne.

zum Standortkontakt

Product downloads

Order now!

  • Data Sheet
  • Brochure ELGUIDER