Sensor roller PD 40

Sensor roller PD 40
Product description
  • Aluminum roller with fixed axis and 2 integrated load cells 
  • Assembly flange at one end for cantilever mounting •
  • Maximum operational reliability due to overload protection up to 10 times the nominal measuring force 
  • Different roller diameters from 60 to 120 mm ensure maximum flexibility 
  • In case of horizontal measuring direction, no influence on the measuring result due to the weight of the roller
Technical Specifications
Accuracy class1
Nominal characteristic value (sensitivity)1m V/V
Combined error< 1%
Characteristic value tolerance0.2%
Measuring principleFull bridge strain gauge
Nominal resistance of the bridge strain gauge700 Ohm
Bridge supply voltage, nominal value10 V
Bridge supply voltage, max. range14 V
Mechanical stop 
  
Operating load0 to 10 mV (with nominal force and a bridge supply voltage of 10 V)
  
 0 to 18 mV (with 1.8 x nominal force and a bridge supply voltage of 10 V)
  
Limit load 
Nominal measuring travel0.15 to 0.25 mm depending on type
Nominal temperature range-10 °C to +60 °C
Operating temperature range-10 °C to +70 °C
Temperature coefficient±0.3% / 10 K (characteristic value)
±0.3% / 10 K (zero signal)
Protection classIP 50
Max. permissible axial transverse force1xFN
Connection cable6x0.14 mm2, 5/10 m long
Kontaktieren
Sie uns!

+49 (0)821/2435-0

Sie haben weitere Fragen? Wir beraten Sie gerne.

zum Standortkontakt

Product downloads

Order now!

  • Data Sheet
  • Brochure ELTENS